engineering plans logo black

FL17409.3-R4

Report Status
Approved
Code Version
2020 Florida Building Code
Application Type
Revision
Folio:
Model:

Amarr Carriage Court (Model 1480)

Database:
Florida Product Approval
Source Link:
Description:

IRC-1409-130-15 Thru 9'-2 wide

Listing Details
Category:
Doors
Subcategory:
Sectional Exterior Door Assemblies
Evaluator:
Thomas L. Shelmerdine - PE-0048579
Validator:
Steven M. Urich, PE
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
November 3, 2020
Validation Date:
November 4, 2020
HVHZ Approved:
No
Impact Resistant:
No [FL]
Design Pressures:
-31.1psf / +26.4psf
Possible CSI Codes:
CSI Code: 08 36 13 - Sectional Doors
CSI Code: 08 17 00 - Integrated Door Opening Assemblies
CSI Code: 08 17 43 - Integrated Composite Door Opening Assemblies
CSI Code: 08 17 23 - Integrated Wood Door Opening Assemblies
CSI Code: 08 16 00 - Composite Doors
Other:
Glazing not available in wind borne debris regions; optional composite overlay
Notes:


Date Submitted: November 3, 2020

Date Validated: November 4, 2020

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: Glazing not available in wind borne debris regions; optional composite overlay

Official Site Status: Approved

Subcategory: Sectional Exterior Door Assemblies
Manufacturer Info
Amarr Garage Doors/Entrematic, established in 1951, is a leading manufacturer of premium garage doors and access systems for residential, commercial, industrial, and agricultural applications. Headquartered in Winston-Salem, North Carolina, the company is renowned for its innovative designs, superior quality, and exceptional customer service, offering a wide range of garage door styles, materials, and automation options to suit diverse requirements and preferences. View all listings
* This manufacturer has not claimed their profile. Any logo or description displayed above has been generated by AI.
Contact Information
Representative:
Robert Richardson
Address:
165 Carriage Court,
Winston-Salem, North Caroli 27105 USA
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 11/03/2024
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL17409 R4 II IRC-1409-130-15 DRAWING 7-16 FL
PR INSTL DOCS FL17409 R4 II IRC-1409-130-15 DRAWING 7-16 FL
PR TECH DOCS FL17409 R4 AE IRC-1409-130-15 EVALUATION REPORT 7-16 FL
PR TECH DOCS FL17409 R4 AE IRC-1409-130-15 EVALUATION REPORT 7-16 FL
PR TECH DOCS FL17409 R4 AE IRC-1409-130-15 REPORT 7-16 FL
PR TECH DOCS FL17409 R4 AE IRC-1409-130-15 REPORT 7-16 FL
QR Code To This Listing
FL17409.3-R4 Listing QR Code
Shopping Cart